What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
483 people
Connections
161
Water source
Groundwater
Based in
St. Louis, LA
County
Lafayette Parish
Owner
Private
The ZIP code it serves

70592

The short answer

2 results are above the health goal. The worst: Arsenic, above the health goal. 6 health-based violations since 2016.

What handles it

What was found

Arsenic, uranium, haloacetic acids (HAA5), total trihalomethanes (TTHM) and nitrate: Louisiana’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2022, with EPA’s 2012 to 2019 file for earlier years.

Fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from May 14, 2012 to Feb. 23, 2018. Newer results are in the utility’s annual water quality report.

Above the health goal2

Arsenic

Comes from the source

Above the health goal

1.2ppb

Highest yearly average, 2021

Averaged by year, the highest was 1.2 ppb, in 2021: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.0 ppb, in 2012.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Uranium

Comes from the source

Above the health goal

0.19ppb

Highest yearly average, 2021

Averaged by year, the highest was 0.19 ppb, in 2021: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file.

What handles it

Below EPA’s limits3

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.32ppm

Highest yearly average, 2012 to 2018

2018 average: 0.2 ppm

Averaged by year, the highest was 0.32 ppm, in 2015, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.32 ppm. In 2018, the latest year on file, its two samples averaged 0.2 ppm.

What handles it

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

3.5ppb

Highest yearly average, 2020 to 2022

2022 average: 2.3 ppb

Averaged by year, the highest was 3.5 ppb, in 2020, below EPA’s legal limit of 60 ppb. In 2022, the latest year on file, it averaged 2.3 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 6.7 ppb, in 2017.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

3.6ppb

Highest yearly average, 2020 to 2022

2022 average: 3.1 ppb

Averaged by year, the highest was 3.6 ppb, in 2020, below EPA’s legal limit of 80 ppb. In 2022, the latest year on file, it averaged 3.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 11.6 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)
  • Lead
  • Nitrate

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claim: Arsenic (Pentavalent)<=50 ppb Reduction

    For: Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Uranium

    For: Arsenic, Uranium

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyJan. 11, 2022—Resolved
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyJan. 11, 2022—Resolved
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyJan. 11, 2022—Resolved
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyJan. 11, 2022—Resolved
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyJan. 11, 2022—Resolved
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencySept. 9, 2019—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 4 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic, uranium, haloacetic acids (HAA5), total trihalomethanes (TTHM) and nitrate results here are Louisiana’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. Magnolia - Garden Heights Subdivision WS’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for Louisiana cover 2020 to 2022; EPA’s compliance samples are from May 14, 2012 to Feb. 23, 2018.

Testing your own tap

Magnolia - Garden Heights Subdivision WS’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Louisiana certifies.

The 3 labs Louisiana certifies closest to the area Magnolia - Garden Heights Subdivision WS serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Element Materials Technology Lafayette, LLC

    Lafayette, LA · about 5 miles

    Certified for lead and copper, metals

  • SGS North America, Inc. - Scott

    Scott, LA · about 14 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

  • LDH Central Laboratory

    Baton Rouge, LA · about 56 miles

    Certified for bacteria

    (225) 219-5200

All 48 certified labs for Louisiana

Sources

PWSID LA1055138. Rebuilt from EPA data on Oct. 18, 2026.