Skip to content
TapBuff

Magnolia - Dixie Garden - Kings Hwy

What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
96 people
Connections
32
Water source
Surface water bought from another system
Based in
St. Louis, LA
County
Caddo Parish
Owner
Private

The short answer

1 result is above EPA’s legal limit. The worst: Total trihalomethanes (TTHM), above the legal limit. 1 health-based violation since 2016.

What handles it

What was found

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Louisiana’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2022, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the legal limit

43.8ppb

Highest yearly average, 2020 to 2022

2022 average: 41.6 ppb

Averaged by year, the highest was 43.8 ppb, in 2020, below EPA’s legal limit of 80 ppb. In 2022, the latest year on file, it averaged 41.6 ppb. EPA judges this limit at each sampling point, and recorded a violation for total trihalomethanes (TTHM) at this utility in 2025. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 35.5 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Below EPA’s limits1

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

24.4ppb

Highest yearly average, 2020 to 2022

Averaged by year, the highest was 24.4 ppb, in 2022, below EPA’s legal limit of 60 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 20.9 ppb, in 2018.

What handles it

No certification claim covers this compound yet.

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

    Other certifiers’ wording: VOC Reduction

  • NSF/ANSI 58

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2025 to Sept. 30, 20250.15 MG/LArchived
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 25 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Louisiana’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Magnolia - Dixie Garden - Kings Hwy’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for Louisiana cover 2020 to 2022.

Testing your own tap

Magnolia - Dixie Garden - Kings Hwy’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Louisiana certifies.

No lab Louisiana certifies is within 75 miles of the area Magnolia - Dixie Garden - Kings Hwy serves on the state’s list. Some take samples by mail; the state’s page lists them all.

All 48 certified labs for Louisiana

Sources

PWSID LA1017087. Rebuilt from EPA data on Oct. 18, 2026.