EPA’s and Louisiana’s records have results for 38 contaminants in its water; 6 were found.

Serves 4,122 people · Groundwater · Lafayette, LA

Serves
4,122 people
Connections
1,374
Water source
Groundwater
Based in
Lafayette, LA
County
Lafayette Parish
Owner
Local government
The 2 ZIP codes it serves

70507, 70520

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

Filters for arsenic, if you want it lower⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from March 20 to Sept. 30, 2024.

Arsenic, nitrate, fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5), chromium (total) and uranium: Louisiana’s own results, samples taken from Sept. 17, 2020 to Sept. 10, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 6 results

Arsenic has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
Lithium, Health reference level 10 ppbAt EPA’s benchmark, as EPA rounds; highest 13.4 ppb

Highest sample, March 20, 2024; found in 2 of 2 · Comes from the source

The highest sample was 13.4 ppb. As EPA rounds results, that is at EPA’s health reference level of 10 ppb, not above it: EPA counts a result as above it from 15 ppb.

What handles it

No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.

How to read your utility’s report
About lithium
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 2.1 ppb

Highest yearly average, 2021 to 2025 · Comes from the source

Averaged by year, the highest was 2.1 ppb, in 2025, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 2.7 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 7.0 ppb, in 2012.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
About arsenic
Nitrate, Legal limit 10 ppm; highest 1.0 ppm

Highest sample; found in 9 of 9 · 2025 average: 0.73 ppm · Comes from the source

The highest sample, in 2022, was 1.0 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its three samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 1.0 ppm, in 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.3 ppm

Highest yearly average, 2021 to 2025 · 2025 average: 0.27 ppm · Forms or is added in treatment

Averaged by year, the highest was 0.3 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.4 ppm. In 2025, the latest year on file, its three samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.32 ppm, in 2015.

What handles it

About fluoride
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 3.6 ppb

Highest yearly average, 2020 to 2026 · Forms or is added in treatment

Averaged by year, the highest was 3.6 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 4.9 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 6.5 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 2.1 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 1.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 2.1 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 2.2 ppb. In 2026, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 8.0 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Utilities above EPA’s PFAS limits, state by state⁠
32 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Chromium (total)
  • Lead
  • Uranium

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. There is 1 monitoring or reporting violation: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claim: Arsenic (Pentavalent)<=50 ppb Reduction

    For: Arsenic

    Other claims that cover it: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claim: Arsenic (Pentavalent)<=50 ppb Reduction

    For: Arsenic

    Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

One more filter
Compare five-year costs

Every filter certified for it⁠

The best reverse osmosis systems, ranked⁠

Disinfectant

Lpwd North Production Facility reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2024 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Arsenic, nitrate, fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5), chromium (total) and uranium results here are Louisiana’s own from 2020 on, with EPA’s national file for 2012 to 2019. Lpwd North Production Facility’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 20 to Sept. 30, 2024; Louisiana’s results run from Sept. 17, 2020 to Sept. 10, 2026.

Testing your own tap

Lpwd North Production Facility’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Louisiana certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Lpwd North Production Facility’s latest lead sampling in EPA’s records, 2024 to 2026, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Louisiana certifies closest to the area Lpwd North Production Facility serves, or a kit by mail

The 3 labs Louisiana certifies closest to the area Lpwd North Production Facility serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • SGS North America, Inc. - Scott

    Scott, LA · about 6 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

  • Element Materials Technology Lafayette, LLC

    Lafayette, LA · about 10 miles

    Certified for lead and copper, metals

  • LDH Central Laboratory

    Baton Rouge, LA · about 52 miles

    Certified for bacteria

    (225) 219-5200

All 48 certified labs for Louisiana⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Louisiana certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Louisiana’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID LA1055171. Rebuilt from EPA data on Oct. 25, 2026.