East Carroll WS South
EPA’s and Louisiana’s records have results for 33 contaminants in its water; 4 were found.
Serves 1,071 people · Groundwater bought from another system · Transylvania, LA
- Serves
- 1,071 people
- Connections
- 357
- Water source
- Groundwater bought from another system
- Based in
- Transylvania, LA
- County
- East Carroll Parish
- Owner
- Private
The ZIP code it serves
The short answer
None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. 10 health-based violations since 2016, 7 with no fix on record in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
Filters for lead, if you want it lowerThe 10 violationsGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Feb. 15 to Aug. 30, 2023.
Lead and copper: EPA SDWIS monitoring periods ending 2008 to 2025.
Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.6 ppm, for the period ending Dec. 31, 2004. None since is on file, so it is not counted as a current finding.
Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Louisiana’s own results, samples taken from July 24, 2020 to July 1, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Above EPA’s health benchmark, 1 result
Lithium
Comes from the source
23.4 ppb
Highest sample, Aug. 30, 2023; found in 2 of 2
The highest sample was 23.4 ppb, about 2.3 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportBelow EPA’s limits, 3 results
Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 57.5 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 45.6 ppb · Forms or is added in treatment
Averaged by year, the highest was 57.5 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 93.1 ppb. In 2026, the latest year on file, its six samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 47 ppb, in 2013.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 14.3 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 10.6 ppb · Forms or is added in treatment
Averaged by year, the highest was 14.3 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 17.4 ppb. In 2026, the latest year on file, its six samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 14.8 ppb, in 2019.
What handles it
No certification claim covers this compound yet.
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.6 ppb
90th percentile, 2023 to 2025 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 1.6 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
29 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
10 health-based violations since 2016, 9 for the Groundwater Rule and 1 for the Lead and Copper Rule Revisions. The latest began Oct. 17, 2024, and 7 have no fix on record in EPA’s file.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Lead and Copper Rule Revisions | The required inventory of lead service lines was not completed or submitted on time.EPA: LSL Inventory | Oct. 17, 2024 | Resolved |
| Groundwater Rule | A significant problem found in a state inspection was not fixed on time.EPA: Failure To Address Deficiency | Aug. 28, 2024 | No fix on recordEPA: unaddressed |
| Aug. 28, 2024 | No fix on recordEPA: unaddressed | ||
| Aug. 28, 2024 | No fix on recordEPA: unaddressed | ||
| Jan. 21, 2023 | No fix on recordEPA: addressed |
The other 5, back to 2016
| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Groundwater Rule | A significant problem found in a state inspection was not fixed on time.EPA: Failure To Address Deficiency | Jan. 21, 2023 | No fix on recordEPA: addressed |
| Jan. 27, 2019 | No fix on recordEPA: addressed | ||
| Jan. 27, 2019 | Resolved | ||
| Jan. 27, 2019 | No fix on recordEPA: addressed | ||
| Feb. 2, 2016 | Resolved |
Health-based violations only. 11 monitoring or reporting violations not shown.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claim: Lead Reduction
For: Lead
- NSF/ANSI 58
Claim: Lead Reduction
For: Lead
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead
Frizzlife SK99 Under Sink Water Filter
Under-sink carbon
Five years: $590, household of 3, cartridges included
Certified for: Lead
2 more filters
Bluevua RO100ROPOT-Lite Countertop Reverse Osmosis System
Countertop reverse osmosis
Five years: $805, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead
Brondell Coral UC300 Under Sink Water Filtration System
Under-sink carbon
Five years: $900, household of 3, cartridges included
Certified for: Lead
Disinfectant
East Carroll WS South reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Louisiana’s own from 2020 on, with EPA’s national file for 2012 to 2019. East Carroll WS South’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 15 to Aug. 30, 2023; Louisiana’s results run from July 24, 2020 to July 1, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. East Carroll WS South’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 1.6 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What East Carroll WS South’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
Labs Louisiana certifies, or a kit by mail
No lab Louisiana certifies is within 75 miles of the area East Carroll WS South serves on the state’s list. Some take samples by mail; the state’s page lists them all.
All 48 certified labs for LouisianaOr test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Louisiana certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Louisiana’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on lithiumWhat it does to health, where it comes from, and the certification claim that addresses it.About lithium
- Get the utility’s own reportEast Carroll WS South must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Louisiana Department of Health, Drinking Water Viewer, results from Jan. 2, 2020 to Oct. 14, 2026, read Oct. 25, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID LA1035007. Rebuilt from EPA data on Oct. 25, 2026.