Skip to content
TapBuff

Cajun Mobile Home Park Water System

What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
168 people
Connections
56
Water source
Groundwater
Based in
Youngsville, LA
County
Lafayette Parish
Owner
Private
The ZIP code it serves

70592

The short answer

2 results are above the health goal. The worst: Lead, above the health goal. 2 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2014 to 2024.

Haloacetic acids (HAA5), nitrate and total trihalomethanes (TTHM): Louisiana’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2022, with EPA’s 2012 to 2019 file for earlier years.

Arsenic, chromium (total), fluoride and uranium: EPA’s compliance monitoring file, samples taken from Oct. 15, 2012 to Sept. 5, 2017. Newer results are in the utility’s annual water quality report.

Above the health goal2

Lead

Comes from pipes, often your own

Above the health goal

13ppb

90th percentile, 2022 to 2024

In the latest period, 9 in 10 homes sampled were at or below 13 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.

What handles it

Arsenic

Comes from the source

Above the health goal

1.7ppb

Highest yearly average, 2012 to 2017

Averaged by year, the highest was 1.7 ppb, in 2017: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 2.0 ppb. That was also the latest year on file.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits5

Chromium (total)

Comes from the source

Below EPA’s limits

7.7ppb

Highest yearly average, 2012 to 2017

2017: not found

Averaged by year, the highest was 7.7 ppb, in 2015, below EPA’s legal limit of 100 ppb. Its highest single sample was 12 ppb. In 2017, the latest year on file, it wasn’t found in any of its three samples.

What handles it

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.28ppm

Highest yearly average, 2012 to 2017

2017 average: 0.2 ppm

Averaged by year, the highest was 0.28 ppm, in 2015, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.28 ppm. In 2017, the latest year on file, its three samples averaged 0.2 ppm.

What handles it

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

2.7ppb

Highest yearly average, 2020 to 2022

Averaged by year, the highest was 2.7 ppb, in 2022, below EPA’s legal limit of 60 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 15.1 ppb, in 2013.

What handles it

No certification claim covers this compound yet.

Nitrate

Comes from the source

Below EPA’s limits

0.4ppm

Highest yearly average, 2022

Averaged by year, the highest was 0.4 ppm, in 2022, below EPA’s legal limit of 10 ppm. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 1.0 ppm, in 2015.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

0.56ppb

Highest yearly average, 2020 to 2022

2022 average: 0.5 ppb

Averaged by year, the highest was 0.56 ppb, in 2020, below EPA’s legal limit of 80 ppb. In 2022, the latest year on file, it averaged 0.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 41.2 ppb, in 2015.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Uranium

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

The best reverse osmosis systems, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyDec. 29, 2021—Unaddressed
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyDec. 29, 2021—Unaddressed
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 13 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), nitrate and total trihalomethanes (TTHM) results here are Louisiana’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Arsenic, chromium (total), fluoride and uranium come from EPA’s file alone, which ends in 2019. Cajun Mobile Home Park Water System’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for Louisiana cover 2020 to 2022; EPA’s compliance samples are from Oct. 15, 2012 to Sept. 5, 2017.

Testing your own tap

Cajun Mobile Home Park Water System’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Louisiana certifies.

The 3 labs Louisiana certifies closest to the area Cajun Mobile Home Park Water System serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Element Materials Technology Lafayette, LLC

    Lafayette, LA · about 5 miles

    Certified for lead and copper, metals

  • SGS North America, Inc. - Scott

    Scott, LA · about 14 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

  • LDH Central Laboratory

    Baton Rouge, LA · about 56 miles

    Certified for bacteria

    (225) 219-5200

All 48 certified labs for Louisiana

Sources

PWSID LA1055121. Rebuilt from EPA data on Oct. 18, 2026.