Skip to content
TapBuff

Labette Co RWD 6

What EPA’s and Kansas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
1,550 people
Connections
557
Water source
Surface water bought from another system
Based in
Coffeyvile, KS
County
Labette
Owner
Local government
The 3 ZIP codes it serves

67337, 67342, 67351

The short answer

1 result is above EPA’s legal limit, and 1 more is above the health goal. The worst: Total trihalomethanes (TTHM), above the legal limit. 3 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2007 to 2025.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Kansas’s own results, samples taken from Jan. 22, 2020 to July 7, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the legal limit

85ppb

Highest yearly average, 2020 to 2026

2026 average: 40 ppb

Averaged by year, the highest was 85 ppb, in 2023, above EPA’s legal limit of 80 ppb. Its highest single sample was 130 ppb. In 2026, the latest year on file, its three samples averaged 40 ppb. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2023 and 2024. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 140 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

10ppb

90th percentile, 2023 to 2025

In the latest period, 9 in 10 homes sampled were at or below 10 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits1

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

34.8ppb

Highest yearly average, 2020 to 2026

2026 average: 7.2 ppb

Averaged by year, the highest was 34.8 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 71 ppb. In 2026, the latest year on file, its three samples averaged 7.2 ppb. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 110 ppb, in 2013.

What handles it

No certification claim covers this compound yet.

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

    Other certifiers’ wording: VOC Reduction

  • NSF/ANSI 58

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2024 to Sept. 30, 20240.083 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2023 to Dec. 31, 20230.085 MG/LResolved
Revised Total Coliform RuleE. coli was confirmed in the water system.EPA: Maximum Contaminant Level Violation, E. coli (RTCR)May 1, 2022 to May 31, 2022—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 2 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Kansas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Labette Co RWD 6’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Kansas’s results run from Jan. 22, 2020 to July 7, 2026.

Testing your own tap

Labette Co RWD 6’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Kansas certifies.

The lab Kansas certifies closest to the area Labette Co RWD 6 serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pace Analytical Services, Inc - Frontenac

    Frontenac, KS · about 52 miles

    Certified for bacteria

    (913) 599-5665

All 47 certified labs for Kansas

Sources

PWSID KS2009916. Rebuilt from EPA data on Oct. 18, 2026.