The short answer
EPA recorded violations of the legal limit for fluoride here in 2024 and 2025. 7 health-based violations since 2016, all resolved in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What handles itThe 7 violationsGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Feb. 3 to Nov. 3, 2025.
Lead and copper: EPA SDWIS monitoring periods ending 2003 to 2025.
Fluoride: EPA’s violation records from 2020 on.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Above the legal limit, 1 result
Fluoride
Forms or is added in treatment
What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days. A filter certified for it, at the tap you drink from, reduces it.
44.5 ppm
Limit violation, 2025
EPA recorded seven violations of the legal limit for fluoride at this utility in 2024 and 2025. The highest measured level, for Jan. 1 to March 31, 2025, was an average of 44.5 ppm, about 11 times EPA’s legal limit of 4.0 ppm.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Below EPA’s limits, 1 result
Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Lead, Action level 15 ppb · health goal zero; 90th percentile 7.6 ppb
90th percentile, 2023 to 2025 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 7.6 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
30 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Fluoride, Lead Reduction
For: Fluoride, Lead
- NSF/ANSI 58
Claims: Fluoride Reduction, Lead Reduction
For: Fluoride, Lead
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Fluoride; also lead, found below its limits
Under-sink reverse osmosis
Five years: $1,149, household of 3, cartridges included
Certified for: Fluoride; also lead, found below its limits
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Fluoride; also lead, found below its limits
2 more filters
Under-sink reverse osmosis
Five years: $1,669, household of 3, cartridges included
Certified for: Fluoride; also lead, found below its limits
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Fluoride; also lead, found below its limits
Every filter certified for it
Disinfectant
Pelham reported disinfecting with chlorine, not chloramine, at all 3 of its sampling points, in its 2025 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
Violations since 2016
7 health-based violations since 2016, all for fluoride. The latest began Oct. 1, 2025.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Fluoride | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2025 to Dec. 31, 2025, 30.2 ppm | Resolved |
| July 1, 2025 to Sept. 30, 2025, 30.9 ppm | Resolved | ||
| April 1, 2025 to June 30, 2025, 38 ppm | Resolved | ||
| Jan. 1, 2025 to March 31, 2025, 44.5 ppm | Resolved | ||
| Oct. 1, 2024 to Dec. 31, 2024, 14.8 ppm | Resolved |
The other 2, back to 2024
| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Fluoride | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2024 to Sept. 30, 2024, 14.9 ppm | Resolved |
| April 1, 2024 to June 30, 2024, 7.8 ppm | Resolved |
Health-based violations only. 1 monitoring or reporting violation not shown.
What this report can’t tell you
Newer results, and everything else. Georgia sent EPA no routine results for its 2012 to 2019 review, so this page has no routine nitrate, arsenic or disinfection byproduct results for Pelham, only the levels behind limit violations EPA recorded since 2020. They are in its own annual report, which it must send you every year.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 3 to Nov. 3, 2025.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Pelham’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 7.6 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What Pelham’s results flag: fluoride. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 2 labs Georgia certifies closest to the area Pelham serves, or a kit by mail
The 2 labs Georgia certifies closest to the area Pelham serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Crystal River Water Services
Norman Park, GA · about 23 miles
Certified for bacteria
Ackurit Labs
Tallahassee, FL · about 43 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Georgia certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Georgia’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on fluorideWhat it does to health, where it comes from, and the certification claim that addresses it.About fluoride
- Get the utility’s own reportPelham must send you a water quality report every year. It has newer results than EPA’s national file, which ends in 2019.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Georgia EPD, laboratories certified by Georgia for chemical, microbiological, PFAS, and lead and copper monitoring, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID GA2050003. Rebuilt from EPA data on Oct. 25, 2026.