The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium, plus lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Oct. 9, 2023 to July 3, 2024.
PFAS: PFBS was found, of the six PFAS in EPA’s 2024 drinking water rule; its result is below. None of the other 23 PFAS tested for was found.
Below EPA’s limits, 1 result
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
PFBS, Health benchmark 2,000 ppt; highest 4.2 ppt
Highest sample, July 3, 2024; found in 2 of 4 · Comes from the source
The highest sample was 4.2 ppt, below EPA’s health benchmark of 2,000 ppt. PFBS has no legal limit or health goal of its own.
What handles it
- NSF/ANSI 53 look for “Total PFAS Reduction”
EPA’s 2024 PFAS rule, compound by compoundAll six, found or not, and the Hazard Index, against the rule’s limits.
| PFAS | EPA’s limit | Result |
|---|---|---|
| PFOA | 4.0 ppt | Not foundNot found in any of 4 samples, below 4 ppt |
| PFOS | 4.0 ppt | Not foundNot found in any of 4 samples, below 4 ppt |
| PFHxS | 10 ppt | Not foundNot found in any of 4 samples, below 3 ppt |
| PFNA | 10 ppt | Not foundNot found in any of 4 samples, below 4 ppt |
| HFPO-DA (GenX) | 10 ppt | Not foundNot found in any of 4 samples, below 5 ppt |
| PFBS | Index only | Below EPA’s limits4.2 ppt highest, found in 2 of 4 samples. Details |
| Hazard IndexPFHxS, PFNA, HFPO-DA and PFBS together | 1 | Doesn’t applyDoesn’t apply: no sampling location found two or more of the four |
| Results from EPA’s UCMR 5 sampling. “Below” is the lab’s reporting level: a result under it reads as not found, which is not the same as zero. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. PFBS has no limit of its own and counts only toward the Hazard Index, which adds up the four, each against EPA’s health-based level, from each sampling location’s average, as EPA’s UCMR 5 summary does. It counts only where two or more of the four were found, and is above the limit from 1.5. | ||
30 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Lead
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Disinfectant
Monroe reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 to 2024 sampling for EPA. It also reported chlorine dioxide.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Newer results, and everything else. Georgia sent EPA no routine results for its 2012 to 2019 review, so this page has no routine nitrate, arsenic or disinfection byproduct results for Monroe. They are in its own annual report, which it must send you every year.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Oct. 9, 2023 to July 3, 2024.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Monroe’s latest lead sampling in EPA’s records, 2024 to 2026, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Georgia certifies closest to the area Monroe serves, or a kit by mail
The 3 labs Georgia certifies closest to the area Monroe serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
UGA Feed and Environmental Water
Athens, GA · about 21 miles
Certified for bacteria
Food and Dairy Research Associates
Commerce, GA · about 30 miles
Certified for bacteria
Eurofins - Atlanta
Atlanta, GA · about 32 miles
Certified for bacteria, lead and copper
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Georgia certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Georgia’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded
- Get the utility’s own reportMonroe must send you a water quality report every year. It has newer results than EPA’s national file, which ends in 2019.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Georgia EPD, laboratories certified by Georgia for chemical, microbiological, PFAS, and lead and copper monitoring, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID GA2970001. Rebuilt from EPA data on Oct. 25, 2026.