Shelter Cove Resort
What EPA’s and Florida’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 187 people
- Connections
- 192
- Water source
- Groundwater
- Based in
- St Cloud, FL
- County
- Osceola
- Owner
- Private
The ZIP code it serves
The short answer
1 result is above EPA’s legal limit. The worst: Total trihalomethanes (TTHM), above the legal limit. 9 health-based violations since 2016.
What handles itWhat was found
Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium: Florida’s own results, samples taken from Feb. 18, 2020 to Sept. 9, 2024, with EPA’s 2012 to 2019 file for earlier years.
Above the legal limit1
Total trihalomethanes (TTHM)
Forms or is added in treatment
94.2ppb
Highest yearly average, 2020 to 2024
2024 average: 42.1 ppb
Averaged by year, the highest was 94.2 ppb, in 2022, above EPA’s legal limit of 80 ppb. Its highest single sample was 144 ppb. In 2024, the latest year on file, its six samples averaged 42.1 ppb. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2021, 2022, 2023 and 2024. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 79.6 ppb, in 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Below EPA’s limits3
Haloacetic acids (HAA5)
Forms or is added in treatment
34.6ppb
Highest yearly average, 2020 to 2024
2024 average: 14.2 ppb
Averaged by year, the highest was 34.6 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 81.6 ppb. In 2024, the latest year on file, its six samples averaged 14.2 ppb. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 53.8 ppb, in 2018.
What handles it
No certification claim covers this compound yet.
Fluoride
Forms or is added in treatment
0.26ppm
Highest yearly average, 2021 to 2024
2024 average: 0.22 ppm
Averaged by year, the highest was 0.26 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2024, the latest year on file, its two samples averaged 0.22 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.28 ppm, in 2018.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate
Comes from the source
0.12ppm
Highest sample; found in 2 of 4
2024, one sample: 0.082 ppm
The highest sample, in 2021, was 0.12 ppm, below EPA’s legal limit of 10 ppm. In 2024, the latest year on file, its one sample was 0.082 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.46 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Chromium (total)
- Lead
- Uranium
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Trihalomethanes (TTHM) Reduction
For: Total trihalomethanes (TTHM)
Other certifiers’ wording: VOC Reduction
- NSF/ANSI 58
Claim: Trihalomethanes (TTHM) Reduction
For: Total trihalomethanes (TTHM)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Aquasana Clean Water Machine (AQ-CWM2)
Countertop
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM)
Brita Hub Countertop Water Filter System (87340)
Countertop
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM)
Ninja HydraSense Countertop Water Filtration System (WF1001)
Countertop
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM)
PUR PLUS Faucet Filtration System, Horizontal (PFM400H)
Faucet mount
- NSF listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 16, 2026
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 16, 2026
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 16, 2026
Certified for: Total trihalomethanes (TTHM)
Brita Elite Water Filter Faucet System (SAFF-100/FF-100)
Faucet mount
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 16, 2026
Certified for: Total trihalomethanes (TTHM)
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2024 to June 30, 2024 | 92 UG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2024 to March 31, 2024 | 110 UG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2023 to Dec. 31, 2023 | 119 UG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2023 to Sept. 30, 2023 | 124 UG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2023 to June 30, 2023 | 108 UG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2023 to March 31, 2023 | 103 UG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2022 to Dec. 31, 2022 | 95.9 UG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2022 to Sept. 30, 2022 | 89.3 UG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2021 to March 31, 2021 | 93.4 UG/L | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 8 monitoring or reporting violations not shown. | ||||
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium results here are Florida’s own from 2020 on, with EPA’s national file for 2012 to 2019. Shelter Cove Resort’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Florida’s results run from Feb. 18, 2020 to Sept. 9, 2024.
Testing your own tap
The 3 labs Florida certifies closest to the area Shelter Cove Resort serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Florida Radiochemistry Services, Inc.
Orlando, FL · about 17 miles
Certified for radioactivity
DOH-EPH Orange Water Testing Laboratory
Orlando, FL · about 22 miles
Certified for bacteria
SGS North America, Inc. - Orlando
Orlando, FL · about 23 miles
Certified for PFAS
Florida Department of Health Bureau of Public Health Laboratories: Coliform and E. coli testing for private wells at the Jacksonville and Miami labs. Collection kits come from your county health department, and the sample has to reach the lab on ice the same day it is collected. $40 for private testing through the state lab. Well Water Testing, Florida Department of Health.
All 212 certified labs for FloridaSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Florida Department of Environmental Protection, Drinking Water Program, results from Jan. 2, 2020 to Dec. 31, 2024, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Florida Department of Health Environmental Laboratory Certification Program, drinking water labs, as listed in TNI LAMS, read Oct. 11, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID FL3491298. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on Total trihalomethanes (TTHM)What each one does to health, where it comes from, and the certification claim that addresses it.About Total trihalomethanes (TTHM)
- Get the utility’s own reportShelter Cove Resort must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs