Pelican Lake Water Plant
What EPA’s and Florida’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 222 people
- Connections
- 69
- Water source
- Groundwater
- Based in
- Pahokee, FL
- County
- Palm Beach
- Owner
- Private
The short answer
1 result is above EPA’s legal limit, and 2 more are above the health goal. The worst: Copper, above the action level. No health-based violations on file since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 2022 to 2025.
Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, chromium (total), fluoride and uranium: Florida’s own results, samples taken from Feb. 19, 2020 to Dec. 5, 2024, with EPA’s 2012 to 2019 file for earlier years.
Above the legal limit1
Copper
Comes from pipes, often your own
1.4ppm
90th percentile, 2025
In the latest period, 9 in 10 homes sampled were at or below 1.4 ppm, above EPA’s action level of 1.3 ppm.
What handles it
- NSF/ANSI 53 look for “Copper Reduction”
- NSF/ANSI 58 look for “Copper Reduction”
Above the health goal2
Lead
Comes from pipes, often your own
10ppb
90th percentile, 2025
In the latest period, 9 in 10 homes sampled were at or below 10 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Arsenic
Comes from the source
0.7ppb
Highest yearly average, 2021 to 2024
Averaged by year, the highest was 0.7 ppb, in 2024: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.1 ppb, in 2018.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Below EPA’s limits3
Total trihalomethanes (TTHM)
Forms or is added in treatment
50.4ppb
Highest yearly average, 2020 to 2024
2024 average: 23.5 ppb
Averaged by year, the highest was 50.4 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 62.1 ppb. In 2024, the latest year on file, its four samples averaged 23.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 59 ppb, in 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5)
Forms or is added in treatment
18ppb
Highest yearly average, 2020 to 2024
Averaged by year, the highest was 18 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 26.8 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 24.6 ppb, in 2019.
What handles it
No certification claim covers this compound yet.
Nitrate
Comes from the source
0.16ppm
Highest sample; found in 1 of 4
2024: not found
The highest sample, in 2020, was 0.16 ppm, below EPA’s legal limit of 10 ppm. In 2024, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.17 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
- Fluoride
- Uranium
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Copper Reduction, Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Copper, Lead, Arsenic
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Copper Reduction, Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Copper, Lead, Arsenic
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Copper, Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Copper, Lead, Arsenic
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 58checked Oct. 9, 2026
Certified for: Copper, Lead, Arsenic
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Copper, Lead, Arsenic
PUR PLUS 11-Cup Pitcher (PPT111W)
Pitcher
- NSF listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
Certified for: Copper, Lead
Violations since 2016
No health-based violations on file with EPA since 2016. There are 16 monitoring or reporting violations: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, chromium (total), fluoride and uranium results here are Florida’s own from 2020 on, with EPA’s national file for 2012 to 2019. Pelican Lake Water Plant’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Florida’s results run from Feb. 19, 2020 to Dec. 5, 2024.
Testing your own tap
The 3 labs Florida certifies closest to the area Pelican Lake Water Plant serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Everglades Laboratories, Inc.
West Palm Beach, FL · about 28 miles
Certified for bacteria
Jupiter Environmental Laboratories, Inc.
Jupiter, FL · about 30 miles
Certified for bacteria, lead and copper, metals, organic chemicals, disinfection byproducts
Eurofins Port St. Lucie
Port St. Lucie, FL · about 34 miles
Certified for bacteria
Florida Department of Health Bureau of Public Health Laboratories: Coliform and E. coli testing for private wells at the Jacksonville and Miami labs. Collection kits come from your county health department, and the sample has to reach the lab on ice the same day it is collected. $40 for private testing through the state lab. Well Water Testing, Florida Department of Health.
All 212 certified labs for FloridaSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Florida Department of Environmental Protection, Drinking Water Program, results from Jan. 2, 2020 to Dec. 31, 2024, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Florida Department of Health Environmental Laboratory Certification Program, drinking water labs, as listed in TNI LAMS, read Oct. 11, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID FL4505002. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 3 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Copper
- Get the utility’s own reportPelican Lake Water Plant must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do