Skip to content
TapBuff

Lake Mary MHP

What EPA’s and Florida’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
150 people
Connections
69
Water source
Groundwater
Based in
Longwood, FL
County
Seminole
Owner
Private
The ZIP code it serves

32750

The short answer

1 result is above EPA’s legal limit. The worst: Copper, above the action level. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2024.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium: Florida’s own results, samples taken from Nov. 24, 2020 to Aug. 8, 2024, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Copper

Comes from pipes, often your own

Above the action level

1.5ppm

90th percentile, 2024

In the latest period, 9 in 10 homes sampled were at or below 1.5 ppm, above EPA’s action level of 1.3 ppm.

What handles it

Below EPA’s limits4

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

46.2ppb

Highest yearly average, 2021 to 2024

2024, one sample: 38.3 ppb

Averaged by year, the highest was 46.2 ppb, in 2022, below EPA’s legal limit of 80 ppb. In 2024, the latest year on file, its one sample was 38.3 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 56.2 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

24.6ppb

Highest yearly average, 2021 to 2024

2024, one sample: 20.1 ppb

Averaged by year, the highest was 24.6 ppb, in 2021, below EPA’s legal limit of 60 ppb. In 2024, the latest year on file, its one sample was 20.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 49.8 ppb, in 2012.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.17ppm

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 0.17 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.38 ppm, in 2015.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.055ppm

Highest sample; found in 1 of 6

2024, one sample: 0.055 ppm

The highest sample, in 2024, was 0.055 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its one sample was 0.055 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.0 ppm, in 2015.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Lead
  • Uranium

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

Violations since 2016

No health-based violations on file with EPA since 2016. There are 29 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium results here are Florida’s own from 2020 on, with EPA’s national file for 2012 to 2019. Lake Mary MHP’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Florida’s results run from Nov. 24, 2020 to Aug. 8, 2024.

Testing your own tap

Lake Mary MHP’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Florida certifies.

The 3 labs Florida certifies closest to the area Lake Mary MHP serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Advanced Environmental Laboratories, Inc. - Orlando

    Altamonte Springs, FL · about 3 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (407) 937-1594

  • Eurofins Orlando

    Altamonte Springs, FL · about 3 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (407) 339-5984

  • EMSL Analytical, Inc. - Orlando

    Orlando, FL · about 11 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, asbestos

    (407) 599-5887

Florida Department of Health Bureau of Public Health Laboratories: Coliform and E. coli testing for private wells at the Jacksonville and Miami labs. Collection kits come from your county health department, and the sample has to reach the lab on ice the same day it is collected. $40 for private testing through the state lab. Well Water Testing, Florida Department of Health.

All 212 certified labs for Florida

Sources

PWSID FL3591248. Rebuilt from EPA data on Oct. 18, 2026.