Skip to content
TapBuff

Holt Water Works, Inc.

What EPA’s and Florida’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
2,582 people
Connections
963
Water source
Groundwater
Based in
Holt, FL
County
Okaloosa
Owner
Local government
The 2 ZIP codes it serves

32531, 32564

The short answer

2 results are above the health goal. The worst: Lead, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 1999 to 2023.

Arsenic, fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate and chromium (total): Florida’s own results, samples taken from April 15, 2020 to July 17, 2024, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal2

Lead

Comes from pipes, often your own

Above the health goal

4.3ppb

90th percentile, 2023

In the latest period, 9 in 10 homes sampled were at or below 4.3 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Arsenic

Comes from the source

Above the health goal

0.35ppb

Highest yearly average, 2021 to 2024

2024 average: 0.3 ppb

Averaged by year, the highest was 0.35 ppb, in 2021: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 0.7 ppb. In 2024, the latest year on file, its two samples averaged 0.3 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.7 ppb, in 2018.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits4

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.51ppm

Highest yearly average, 2021 to 2024

2024 average: 0.48 ppm

Averaged by year, the highest was 0.51 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.54 ppm. In 2024, the latest year on file, its four samples averaged 0.48 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.51 ppm, in 2012.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

10.1ppb

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 10.1 ppb, in 2024, below EPA’s legal limit of 80 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 16.6 ppb, in 2014.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

1.4ppb

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 1.4 ppb, in 2024, below EPA’s legal limit of 60 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.5 ppb, in 2012.

What handles it

No certification claim covers this compound yet.

Nitrate

Comes from the source

Below EPA’s limits

0.042ppm

Highest sample; found in 2 of 8

2024: not found

The highest sample, in 2020, was 0.042 ppm, below EPA’s legal limit of 10 ppm. In 2024, the latest year on file, it wasn’t found in any of its two samples. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.03 ppm, in 2014.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

The best reverse osmosis systems, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 7 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Arsenic, fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate and chromium (total) results here are Florida’s own from 2020 on, with EPA’s national file for 2012 to 2019. Holt Water Works, Inc.’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Florida’s results run from April 15, 2020 to July 17, 2024.

Testing your own tap

Holt Water Works, Inc.’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Florida certifies.

The 3 labs Florida certifies closest to the area Holt Water Works, Inc. serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Future Laboratories, Inc.

    Milton, FL · about 14 miles

    Certified for bacteria

    (850) 623-6110

  • Analytical Services Corporation

    Niceville, FL · about 27 miles

    Certified for bacteria

    (850) 678-5313

  • Destin Water Users, Inc.

    Destin, FL · about 32 miles

    Certified for bacteria, nitrate

    (850) 837-6146

Florida Department of Health Bureau of Public Health Laboratories: Coliform and E. coli testing for private wells at the Jacksonville and Miami labs. Collection kits come from your county health department, and the sample has to reach the lab on ice the same day it is collected. $40 for private testing through the state lab. Well Water Testing, Florida Department of Health.

All 212 certified labs for Florida

Sources

PWSID FL1460352. Rebuilt from EPA data on Oct. 18, 2026.