What EPA’s and Florida’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
1,573 people
Connections
697
Water source
Groundwater
Based in
Palm City, FL
County
St. Lucie
Owner
Private
The ZIP code it serves

34990

The short answer

Nothing in EPA’s and Florida’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.

What was found

Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, arsenic, chromium (total) and fluoride: Florida’s own results, samples taken from Aug. 26, 2020 to Aug. 21, 2024, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits3

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

16.6ppb

Highest yearly average, 2020 to 2024

2024 average: 11.4 ppb

Averaged by year, the highest was 16.6 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 18.7 ppb. In 2024, the latest year on file, its two samples averaged 11.4 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 28.3 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

16.5ppb

Highest yearly average, 2020 to 2024

2024 average: 7.8 ppb

Averaged by year, the highest was 16.5 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 18.7 ppb. In 2024, the latest year on file, its two samples averaged 7.8 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 49.9 ppb, in 2015.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

0.26ppm

Highest sample; found in 2 of 4

2024 average: 0.087 ppm

The highest sample, in 2024, was 0.26 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its three samples averaged 0.087 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.6 ppm, in 2016.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Fluoride
  • Lead

Violations since 2016

No health-based violations on file with EPA since 2016. There are 35 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, arsenic, chromium (total) and fluoride results here are Florida’s own from 2020 on, with EPA’s national file for 2012 to 2019. Harbour Ridge’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Florida’s results run from Aug. 26, 2020 to Aug. 21, 2024.

Testing your own tap

Harbour Ridge’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Florida certifies.

The 3 labs Florida certifies closest to the area Harbour Ridge serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins Port St. Lucie

    Port St. Lucie, FL · about 14 miles

    Certified for bacteria

    (772) 343-8006

  • Jupiter Environmental Laboratories, Inc.

    Jupiter, FL · about 19 miles

    Certified for bacteria, lead and copper, metals, organic chemicals, disinfection byproducts

    (561) 575-0030

  • Everglades Laboratories, Inc.

    West Palm Beach, FL · about 30 miles

    Certified for bacteria

    (561) 833-4200

Florida Department of Health Bureau of Public Health Laboratories: Coliform and E. coli testing for private wells at the Jacksonville and Miami labs. Collection kits come from your county health department, and the sample has to reach the lab on ice the same day it is collected. $40 for private testing through the state lab. Well Water Testing, Florida Department of Health.

All 212 certified labs for Florida

Sources