Skip to content
TapBuff

Emil - Mar Subdivision

What EPA’s and Florida’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
203 people
Connections
81
Water source
Groundwater
Based in
Ocala, FL
County
Marion
Owner
Public and private

The short answer

1 result is above the health goal. The worst: Uranium, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Uranium, nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, arsenic and chromium (total): Florida’s own results, samples taken from Jan. 7, 2020 to Oct. 25, 2024, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal1

Uranium

Comes from the source

Above the health goal

0.74ppb

Highest yearly average, 2024

Averaged by year, the highest was 0.74 ppb, in 2024: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file.

What handles it

Below EPA’s limits4

Nitrate

Comes from the source

Below EPA’s limits

7.3ppm

Highest sample; found in 16 of 16

2024 average: 4.8 ppm

The highest sample, in 2021, was 7.3 ppm, below EPA’s legal limit of 10 ppm. In 2024, the latest year on file, its four samples averaged 4.8 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 6.9 ppm, in 2013.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

40.5ppb

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 40.5 ppb, in 2024, below EPA’s legal limit of 80 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 43.5 ppb, in 2012.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

10.3ppb

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 10.3 ppb, in 2024, below EPA’s legal limit of 60 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 6.4 ppb, in 2012.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.042ppm

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 0.042 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.043 ppm, in 2018.

What handles it

3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

None of the filters TapBuff has checked so far carry these claims. Search the certifier listings for the claim above.

Compare five-year costs

Violations since 2016

No health-based violations on file with EPA since 2016. There are 8 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Uranium, nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, arsenic and chromium (total) results here are Florida’s own from 2020 on, with EPA’s national file for 2012 to 2019. Emil - Mar Subdivision’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Florida’s results run from Jan. 7, 2020 to Oct. 25, 2024.

Testing your own tap

Emil - Mar Subdivision’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Florida certifies.

No lab Florida certifies is within 75 miles of the area Emil - Mar Subdivision serves on the state’s list. Some take samples by mail; the state’s page lists them all.

Florida Department of Health Bureau of Public Health Laboratories: Coliform and E. coli testing for private wells at the Jacksonville and Miami labs. Collection kits come from your county health department, and the sample has to reach the lab on ice the same day it is collected. $40 for private testing through the state lab. Well Water Testing, Florida Department of Health.

All 212 certified labs for Florida

Sources

PWSID FL3420340. Rebuilt from EPA data on Oct. 18, 2026.