Skip to content
TapBuff

Cedar Key WTP

What EPA’s and Florida’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
735 people
Connections
1,018
Water source
Groundwater
Based in
Cedar Key, FL
County
Levy
Owner
Local government
The ZIP code it serves

32625

The short answer

1 result is above EPA’s legal limit, and 2 more are above the health goal. The worst: Total trihalomethanes (TTHM), above the legal limit. 13 health-based violations since 2016.

What handles it

What was found

Total trihalomethanes (TTHM), arsenic, haloacetic acids (HAA5), chromium (total), fluoride and nitrate: Florida’s own results, samples taken from Feb. 3, 2020 to Aug. 20, 2024, with EPA’s 2012 to 2019 file for earlier years.

Uranium: EPA’s compliance monitoring file, samples taken from July 9, 2012 to July 9, 2012. Newer results are in the utility’s annual water quality report.

Above the legal limit1

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the legal limit

97.3ppb

Highest yearly average, 2020 to 2024

2024 average: 37 ppb

Averaged by year, the highest was 97.3 ppb, in 2020, above EPA’s legal limit of 80 ppb. Its highest single sample was 161 ppb. In 2024, the latest year on file, its two samples averaged 37 ppb. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2020 and 2021. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 146 ppb, in 2017, and EPA recorded violations in 2017, 2018 and 2019.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Above the health goal2

Arsenic

Comes from the source

Above the health goal

0.8ppb

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 0.8 ppb, in 2024: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.2 ppb, in 2012.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Uranium

Comes from the source

Above the health goal

1.5ppb

Highest yearly average, 2012

Averaged by year, the highest was 1.5 ppb, in 2012: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file.

What handles it

Below EPA’s limits1

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

35.2ppb

Highest yearly average, 2020 to 2024

2024 average: 11.1 ppb

Averaged by year, the highest was 35.2 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 41 ppb. In 2024, the latest year on file, its two samples averaged 11.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 108 ppb, in 2017, and EPA recorded a violation in 2017.

What handles it

No certification claim covers this compound yet.

4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)
  • Fluoride
  • Lead
  • Nitrate

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Total trihalomethanes (TTHM), Arsenic

    Other certifiers’ wording: VOC Reduction; Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Uranium

    For: Total trihalomethanes (TTHM), Arsenic, Uranium

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2021 to March 31, 202186.9 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2020 to Dec. 31, 202098.2 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2020 to Sept. 30, 202083.8 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2020 to June 30, 2020104 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2020 to March 31, 2020101 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2019 to Dec. 31, 2019100 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2019 to Sept. 30, 201991.9 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2018 to June 30, 2018102 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2018 to March 31, 2018102 UG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2017 to Dec. 31, 2017112 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2017 to Dec. 31, 2017146 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 2017164 UG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 2017134 UG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 5 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), arsenic, haloacetic acids (HAA5), chromium (total), fluoride and nitrate results here are Florida’s own from 2020 on, with EPA’s national file for 2012 to 2019. Uranium comes from EPA’s file alone, which ends in 2019. Cedar Key WTP’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Florida’s results run from Feb. 3, 2020 to Aug. 20, 2024; EPA’s compliance samples are from July 9, 2012 to July 9, 2012.

Testing your own tap

Cedar Key WTP’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Florida certifies.

The 3 labs Florida certifies closest to the area Cedar Key WTP serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Advanced Environmental Laboratories, Inc. - Gainesville

    Gainesville, FL · about 44 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (352) 377-2349

  • FL Dept. of Health - Alachua County Health Department

    Gainesville, FL · about 54 miles

    Certified for bacteria

    (352) 334-7930

  • Aqua Pure Water & Sewage Service, LLC

    Ocala, FL · about 55 miles

    Certified for bacteria

    (352) 355-2383

Florida Department of Health Bureau of Public Health Laboratories: Coliform and E. coli testing for private wells at the Jacksonville and Miami labs. Collection kits come from your county health department, and the sample has to reach the lab on ice the same day it is collected. $40 for private testing through the state lab. Well Water Testing, Florida Department of Health.

All 212 certified labs for Florida

Sources

PWSID FL2380178. Rebuilt from EPA data on Oct. 18, 2026.