Ctwc - Naugatuck Region - Central System
EPA’s and CDC’s records have results for 38 contaminants in its water; 4 were found.
Serves 22,735 people · Surface water · Beacon Falls, CT
- Serves
- 22,735 people
- Connections
- 11,186
- Water source
- Surface water
- Based in
- Beacon Falls, CT
- County
- New Haven
- Owner
- Private
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from April 11, 2023 to Jan. 16, 2024.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic and uranium: Connecticut’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2023, with EPA’s 2012 to 2019 file for earlier years.
Fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from April 24, 2012 to Jan. 18, 2019. Newer results are in the utility’s annual water quality report.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Below EPA’s limits, 4 results
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 31.6 ppb
Highest yearly average, 2020 to 2023 · 2023 average: 27.6 ppb · Forms or is added in treatment
Averaged by year, the highest was 31.6 ppb, in 2022, below EPA’s legal limit of 80 ppb. In 2023, the latest year on file, it averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 39.7 ppb, in 2017.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 12.9 ppb
Highest yearly average, 2020 to 2023 · Forms or is added in treatment
Averaged by year, the highest was 12.9 ppb, in 2023, below EPA’s legal limit of 60 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 14.8 ppb, in 2015.
What handles it
No certification claim covers this compound yet.
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.69 ppm
Highest yearly average, 2012 to 2019 · 2019 average: 0.36 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.69 ppm, in 2012, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 1.2 ppm. In 2019, the latest year on file, its two samples averaged below the limit.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate, Legal limit 10 ppm; highest yearly average 0.53 ppm
Highest yearly average, 2020 to 2023 · 2023 average: 0.27 ppm · Comes from the source
Averaged by year, the highest was 0.53 ppm, in 2021, below EPA’s legal limit of 10 ppm. In 2023, the latest year on file, it averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 2.3 ppm, in 2017.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
34 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Arsenic
- Chromium (total)
- Lead
- Uranium
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Disinfectant
Ctwc - Naugatuck Region - Central System reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 to 2024 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic and uranium results here are Connecticut’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. Ctwc - Naugatuck Region - Central System’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from April 11, 2023 to Jan. 16, 2024; CDC’s yearly averages for Connecticut cover 2020 to 2023; EPA’s compliance samples are from April 24, 2012 to Jan. 18, 2019.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Ctwc - Naugatuck Region - Central System’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Connecticut certifies closest to the area Ctwc - Naugatuck Region - Central System serves, or a kit by mail
The 3 labs Connecticut certifies closest to the area Ctwc - Naugatuck Region - Central System serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Northwest Environmental Water Labs
Waterbury, CT · about 3 miles
Certified for bacteria, nitrate, metals, minerals and other inorganics
Aquatek Labs, Inc.
Woodbridge, CT · about 10 miles
Certified for bacteria, nitrate, metals, minerals and other inorganics, organic chemicals, radioactivity
EMSL Analytical, Inc. - CT
Meriden, CT · about 11 miles
Certified for bacteria, asbestos
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Connecticut certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Connecticut’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded
- Get the utility’s own reportCtwc - Naugatuck Region - Central System must send you a water quality report every year. It covers contaminants this page does not show, and has newer results than EPA’s national file for the ones here that come from it.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- CDC Environmental Public Health Tracking Network, yearly averages Connecticut supplied to CDC, 2020 to 2023, read Oct. 8, 2026. TapBuff’s comparisons with EPA’s limits are its own, not CDC’s or Connecticut’s.
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Connecticut DPH, approved commercial laboratories certified to test drinking water, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CT0880011. Rebuilt from EPA data on Oct. 25, 2026.