15th Avenue
What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 50 people
- Connections
- 3
- Water source
- Groundwater
- Based in
- Stockton, CA
- County
- Kings
- Owner
- Private
The short answer
1 result is above EPA’s legal limit, 1 more is above the limit’s level with no violation recorded, and 1 more is above the health goal. The worst: Lead, above the action level. No health-based violations on file since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 2011 to 2025.
Arsenic, uranium, fluoride, nitrate, chromium (total), haloacetic acids (HAA5) and total trihalomethanes (TTHM): California’s own results, samples taken from Jan. 6, 2020 to July 6, 2026, with EPA’s 2012 to 2019 file for earlier years.
Above the legal limit1
Lead
Comes from pipes, often your own
27.5ppb
90th percentile, 2023 to 2025
In the latest period, 9 in 10 homes sampled were at or below 27.5 ppb, above EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Above the limit’s level, no violation recorded1
Arsenic
Comes from the source
42.8ppb
Highest yearly average, 2020 to 2026
2026 average: 30.9 ppb
Averaged by year, the highest was 42.8 ppb, in 2024, about 4.3 times EPA’s legal limit of 10 ppb. Its highest single sample was 103 ppb. In 2026, the latest year on file, its 21 samples averaged 30.9 ppb, above the limit. EPA judges this limit on running averages at each sampling point, and recorded no violation for arsenic at this utility since 2020. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 37.4 ppb, in 2015.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Above the health goal1
Uranium
Comes from the source
8.7ppb
Highest yearly average, 2024 to 2026
2026 average: 2.2 ppb
Averaged by year, the highest was 8.7 ppb, in 2024: below EPA’s legal limit of 30 ppb, but above its health goal of zero. Its highest single sample was 10.8 ppb. In 2026, the latest year on file, its 14 samples averaged 2.2 ppb.
What handles it
- NSF/ANSI 58 look for “Uranium”
Below EPA’s limits2
Fluoride
Forms or is added in treatment
1.4ppm
Highest yearly average, 2021 to 2024
Averaged by year, the highest was 1.4 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.9 ppm, in 2015.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate
Comes from the source
0.4ppm
Highest sample; found in 1 of 6
2026: not found
The highest sample, in 2021, was 0.4 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in its one sample.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
- Haloacetic acids (HAA5)
- Total trihalomethanes (TTHM)
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Uranium
For: Lead, Arsenic, Uranium
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead, Arsenic
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Lead, Arsenic
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Violations since 2016
No health-based violations on file with EPA since 2016.
What this report can’t tell you
Everything else. Arsenic, uranium, fluoride, nitrate, chromium (total), haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. 15th Avenue’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from Jan. 6, 2020 to July 6, 2026.
Testing your own tap
No lab California certifies is within 75 miles of the area 15th Avenue serves on the state’s list. Some take samples by mail; the state’s page lists them all.
All 145 certified labs for CaliforniaSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- California State Water Resources Control Board, Division of Drinking Water, results from Jan. 1, 2020 to July 17, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CA1600293. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 3 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Lead
- Get the utility’s own report15th Avenue must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs