Skip to content
TapBuff

Rampart Washeteria

EPA’s and Alaska’s records have results for 9 contaminants in its water; 7 were found.

Serves 88 people · Groundwater · Rampart, AK

Serves
88 people
Connections
5
Water source
Groundwater
Based in
Rampart, AK
County
Yukon - Koyukuk Census Area
Owner
Native American
The ZIP code it serves

99767

The short answer

Copper is above the action level in the latest monitoring period, ending June 30, 2026. 12 health-based violations since 2016, 5 with no fix on record in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠The 12 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

Lead and copper: EPA SDWIS monitoring periods ending 2017 to 2026.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), fluoride, nitrate, chromium (total) and arsenic: Alaska’s own results, samples taken from March 31, 2020 to June 30, 2025, with EPA’s 2012 to 2019 file for earlier years.

Uranium: EPA’s compliance monitoring file, samples taken from March 29, 2016 to Nov. 28, 2016. Newer results are in the utility’s annual water quality report.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

Above the legal limit, 1 result

Copper

Comes from pipes, often your own

Above the action level

What it means for you. EPA’s concern is stomach and intestinal distress from short-term exposure, and liver or kidney damage over years. A filter certified for it, at the tap you drink from, reduces it.

2.6 ppm

90th percentile, 2026

In the latest period, 9 in 10 homes sampled were at or below 2.6 ppm, above EPA’s action level of 1.3 ppm.

What handles it

Below EPA’s limits, 6 results

Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 41.9 ppb

Highest yearly average, 2021 to 2025 · 2025: not found · Forms or is added in treatment

Averaged by year, the highest was 41.9 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 115 ppb. In 2025, the latest year on file, it wasn’t found in its one sample. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 11 ppb, in 2017.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 55.7 ppb

Highest yearly average, 2021 to 2025 · 2025: not found · Forms or is added in treatment

Averaged by year, the highest was 55.7 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 160 ppb. In 2025, the latest year on file, it wasn’t found in its one sample. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 7.1 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.5 ppb

90th percentile, 2026 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 1.5 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.2 ppm

Highest yearly average, 2021 · Forms or is added in treatment

Averaged by year, the highest was 0.2 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. That is the only year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.1 ppm, in 2016.

What handles it

About fluoride
Nitrate, Legal limit 10 ppm; highest 0.25 ppm

Highest sample; found in 1 of 2 · 2023, one sample: 0.25 ppm · Comes from the source

The highest sample, in 2023, was 0.25 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 2.2 ppm, in 2017.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Chromium (total), Legal limit 100 ppb; highest yearly average 1.5 ppb

Highest yearly average, 2021 · Comes from the source

Averaged by year, the highest was 1.5 ppb, in 2021, below EPA’s legal limit of 100 ppb. That is the only year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 1.7 ppb, in 2016.

What handles it

About chromium (total)
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Uranium

Violations since 2016

12 health-based violations since 2016, all for the Groundwater Rule. The latest began April 26, 2026, and 5 have no fix on record in EPA’s file.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyApril 26, 2026No fix on recordEPA: unaddressed
April 26, 2026Resolved
April 26, 2026No fix on recordEPA: unaddressed
April 26, 2026No fix on recordEPA: unaddressed
April 26, 2026No fix on recordEPA: unaddressed
The other 7, back to 2023
Earlier health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyApril 26, 2026No fix on recordEPA: unaddressed
Jan. 8, 2023Resolved
Jan. 8, 2023Resolved
Jan. 8, 2023Resolved
Jan. 8, 2023Resolved
Jan. 8, 2023Resolved
Jan. 8, 2023Resolved

Health-based violations only. 179 monitoring or reporting violations not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Copper Reduction, Lead Reduction

    For: Copper, Lead

  • NSF/ANSI 58

    Claims: Copper Reduction, Lead Reduction

    For: Copper, Lead

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for lead, ranked⁠

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), fluoride, nitrate, chromium (total) and arsenic results here are Alaska’s own from 2020 on, with EPA’s national file for 2012 to 2019. Uranium comes from EPA’s file alone, which ends in 2019. Rampart Washeteria’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Alaska’s results run from March 31, 2020 to June 30, 2025; EPA’s compliance samples are from March 29 to Nov. 28, 2016.

Testing your own tap

Rampart Washeteria’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Alaska certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Rampart Washeteria’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 1.5 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The lab Alaska certifies closest to the area Rampart Washeteria serves, or a kit by mail

The lab Alaska certifies closest to the area Rampart Washeteria serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pollen Environmental, LLC

    Fairbanks, AK · about 72 miles

    Certified for bacteria, nitrate

    (907) 479-8368

All 37 certified labs for Alaska⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Alaska certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Alaska’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID AK2360816. Rebuilt from EPA data on Oct. 25, 2026.