EPA’s and Alabama’s records have results for 33 contaminants in its water; 2 were found.

Serves 4,386 people · Surface water bought from another system · Fayette, AL

Serves
4,386 people
Connections
1,462
Water source
Surface water bought from another system
Based in
Fayette, AL
County
Fayette
Owner
Local government
The ZIP code it serves

35555

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Jan. 10 to Oct. 23, 2023.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Alabama’s own results, samples taken from Feb. 4, 2020 to Aug. 3, 2026, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 2 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 58.2 ppb

Highest yearly average, 2020 to 2026 · Forms or is added in treatment

Averaged by year, the highest was 58.2 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 110 ppb. That was also the latest year on file. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 60.9 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 41.8 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 37.8 ppb · Forms or is added in treatment

Averaged by year, the highest was 41.8 ppb, in 2025, below EPA’s legal limit of 60 ppb. Its highest single sample was 80 ppb. In 2026, the latest year on file, its six samples averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 42.5 ppb, in 2014.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Alabama utilities above EPA’s PFAS limits⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Disinfectant

Fayette Co., Water Coord. & F. P. A. reported disinfecting with chlorine, not chloramine, at all 3 of its sampling points, in its 2023 sampling for EPA. It also reported permanganate.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Alabama’s own from 2020 on, with EPA’s national file for 2012 to 2019. Fayette Co., Water Coord. & F. P. A.’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 10 to Oct. 23, 2023; Alabama’s results run from Feb. 4, 2020 to Aug. 3, 2026.

Testing your own tap

Fayette Co., Water Coord. & F. P. A.’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Alabama certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Fayette Co., Water Coord. & F. P. A.’s latest lead sampling in EPA’s records, 2021 to 2023, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Alabama certifies closest to the area Fayette Co., Water Coord. & F. P. A. serves, or a kit by mail

The 3 labs Alabama certifies closest to the area Fayette Co., Water Coord. & F. P. A. serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pace Analytical Services

    Tuscaloosa, AL · about 36 miles

    Certified for bacteria

    (205) 345-0816

  • Safety Environmental Services

    Pelham, AL · about 59 miles

    Certified for bacteria

    (205) 823-6200

  • Sutherland Environmental Testing Laboratory

    Birmingham, AL · about 59 miles

    (205) 581-9500

All 64 certified labs for Alabama⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Alabama certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Alabama’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID AL0000594. Rebuilt from EPA data on Oct. 25, 2026.